What's happening
This bill adds fuel-flexible linear generator electric generating equipment to New York's net energy metering and renewable energy laws.
Why it matters
Expanding eligible technologies can accelerate adoption of distributed generation. By adding fuel-flexible linear generators to net metering and renewable energy programs, the bill creates new incentives for consumers and businesses to invest in this technology, potentially leading to more local electricity generation and grid resiliency.
Fuel-flexible linear generators offer operational advantages over traditional renewables. Unlike solar or wind, these generators can produce electricity on demand and use various fuels, which may help address the intermittency of renewables and support grid stability, especially during peak demand or outages.
Defining what qualifies as a renewable fuel matters for future energy policy. The bill allows only those linear generators that do not use fossil fuels to qualify as “renewable energy systems,” which could drive innovation toward cleaner fuels and help New York meet its climate and emissions goals.
Potential infrastructure and rate impacts for utility customers. The bill sets rules for how costs of new grid equipment and interconnections for these generators are shared, which could affect installation economics for adopters and influence how utilities manage integration of new distributed resources.
Albany, before your first meeting.
Every bill that moved yesterday, summarized in a sentence and ranked by impact. The Albany Scorecard follows on Sundays.
Free. Unsubscribe in one click. Want alerts on specific bills? Create an account.
Who cares
Residential and business electricity customers
Those using qualifying fuel-flexible linear generators would gain access to net metering, with surplus electricity credited at the utility’s avoided costs.
Electric utilities
The bill would require them to interconnect qualifying linear generators and provide net metering under the section’s capacity limits and safety requirements.
Fuel-flexible linear generator manufacturers and developers
The bill would recognize their equipment as an alternate energy production technology and classify generators that do not use fossil fuels as renewable energy systems.
Farm operators
Those installing qualifying linear generators could allocate net metering credits among their properties within the same utility service territory and load zone.
Headline styles
Add New Generator to Net Metering
Plain English, a few words. Used as the page title.
Sponsors
No co-sponsors yet.
History
- Amended by restoring to previous print 1163a
- Print number 1163b
- Amend and recommit to energy and telecommunications
- Print number 1163a
- Amend and recommit to energy and telecommunications
- Referred to energy and telecommunications
Companion bill
The same bill in the other chamber. A bill becomes law when one version passes both houses and the governor signs it, so either number can carry it.
Add Linear Generators to Net Metering
Signed by Governor · Sponsor Michael Cusick
Full text
4 pagesUnderlined is new[Struck] is removedOfficial text on nysenate.gov ↗
STATE OF NEW YORK
1163--A
2021-2022 Regular Sessions
IN SENATE
January 7, 2021
Introduced by Sen. BENJAMIN -- read twice and ordered printed, and when printed to be committed to the Committee on Energy and Telecommunications -- committee discharged, bill amended, ordered reprinted as amended and recommitted to said committee
AN ACT to amend the public service law, in relation to net energy metering for fuel-flexible linear generator electric generating equipment
The People of the State of New York, represented in Senate and Assembly, do enact as follows:
Section 1. Subdivision 2-b of section 2 of the public service law, as amended by chapter 6 of the laws of 2011, is amended to read as follows:
2-b. The term "alternate energy production facility," when used in this chapter, includes any solar, wind turbine, fuel cell, fuel-flexible linear generator electric generating equipment, tidal, wave energy, waste management resource recovery, refuse-derived fuel, wood burning facility, or energy storage device utilizing batteries, flow batteries, flywheels or compressed air, together with any related facilities located at the same project site, with an electric generating capacity of up to eighty megawatts, which produces electricity, gas or useful thermal energy.
§ 2. The section heading of section 66-j of the public service law, as amended by chapter 546 of the laws of 2011, is amended to read as follows:
Net energy metering for residential solar, farm waste, non-residential solar electric generating systems, micro-combined heat and power generating equipment, fuel cell electric generating equipment, fuel-flexible linear generator electric generating equipment, and micro-hydroelectric generating equipment.
§ 3. Subparagraphs (v) and (vi) of paragraph (a) of subdivision 1 of section 66-j of the public service law, subparagraph (v) as separately amended by chapters 530 and 546 of the laws of 2011 and subparagraph (vi) as added by chapter 530 of the laws of 2011, are amended to read as follows:
(v) a residential customer of an electric corporation who owns, leases or operates fuel cell generating equipment or fuel-flexible linear
EXPLANATION--Matter in italics (underscored) is new; matter in brackets
[ ] is old law to be omitted.
LBD04973-03-1
S. 1163--A 2
generator electric generating equipment located on the customer's premises; and (vi) a non-residential customer of an electric corporation who owns, leases or operates fuel cell generating equipment or fuel-flexible linear generator electric generating equipment located and used at the customer's premises;
§ 4. Paragraph (f) of subdivision 1 of section 66-j of the public service law, as added by chapter 355 of the laws of 2009, is amended to read as follows:
(f) "Micro-combined heat and power generating equipment" means an integrated, cogenerating building heating and electrical power generation system, operating on any fuel and of any applicable engine, fuel cell, fuel-flexible linear generator, or other technology, with a rated capacity of at least one kilowatt and not more than ten kilowatts electric and any thermal output that at full load has a design total fuel use efficiency in the production of heat and electricity of not less than eighty percent, and annually produces at least two thousand kilowatt hours of useful energy in the form of electricity that may work in combination with supplemental or parallel conventional heating systems, that is manufactured, installed and operated in accordance with applicable government and industry standards, that is connected to the electric system and operated in conjunction with an electric corporation's transmission and distribution facilities.
§ 5. Subdivision 1 of section 66-j of the public service law is amended by adding a new paragraph (i) to read as follows:
(i) "Fuel-flexible linear generator electric generating equipment" or "fuel-flexible linear generator" means an integrated system consisting of oscillators, cylinders, electricity conversion equipment and associated balance of plant components that directly convert the linear motion of the oscillators into electricity and which has a combined rated capacity of not more than two thousand kilowatts.
§ 6. Subdivision 2 of section 66-j of the public service law, as amended by chapter 546 of the laws of 2011, is amended to read as follows:
2. Interconnection and net energy metering. An electric corporation shall provide for the interconnection of solar and farm waste electric generating equipment, micro-combined heat and power generating equipment, fuel cell electric generating equipment, fuel-flexible linear generator electric generating equipment and micro-hydroelectric generating equipment owned or operated by a customer-generator and for net energy metering, provided that the customer-generator enters into a net energy metering contract with the corporation or complies with the corporation's net energy metering schedule and complies with standards and requirements established under this section.
§ 7. Subparagraph (iii) of paragraph (a) of subdivision 3 of section 66-j of the public service law, as amended by chapter 546 of the laws of 2011, is amended to read as follows:
(iii) Each electric corporation shall make such contract and schedule available to customer-generators on a first come, first served basis, until the total rated generating capacity for solar and farm waste electric generating equipment, micro-combined heat and power generating equipment, fuel cell electric generating equipment, fuel-flexible linear generator electric generating equipment and micro-hydroelectric generating equipment owned, leased or operated by customer-generators in the corporation's service area is equivalent to one percent of the corporation's electric demand for the year two thousand five, as determined by the department.
S. 1163--A 3
§ 8. Paragraph (c) of subdivision 3 of section 66-j of the public service law, as amended by chapter 546 of the laws of 2011, subparagraph (iii) as amended by chapter 494 of the laws of 2014, is amended to read as follows:
(c) In the event that the electric corporation determines that it is necessary to install a dedicated transformer or transformers, or other equipment to protect the safety and adequacy of electric service provided to other customers, a customer-generator shall pay the electric corporation's actual costs of installing the transformer or transformers, or other equipment:
(i) In the case of a customer-generator who owns or operates solar electric generating equipment, micro-combined heat and power generating equipment, fuel cell electric generating equipment, fuel-flexible linear generator electric generating equipment or micro-hydroelectric generating equipment located and used at his or her residence, or a non-residential customer-generator who owns or operates solar electric generating equipment with a rated capacity of not more than twenty-five kilowatts, up to a maximum amount of three hundred fifty dollars;
(ii) In the case of a customer-generator who owns or operates farm waste electric generating equipment located and used at his or her "farm operation," up to a total amount of five thousand dollars per "farm operation"; and
(iii) In the case of a non-residential customer-generator who owns or operates solar electric generating equipment or fuel cell electric generating equipment or fuel-flexible linear generator electric generating equipment or micro-hydroelectric generating equipment or farm waste generating equipment as described in subparagraph (ix) of paragraph (a) of subdivision one of this section, with a rated capacity of more than twenty-five kilowatts located and used at its premises, such cost shall be as determined by the electric corporation subject to review, upon the request of such customer-generator, by the department.
§ 9. Paragraph (g) of subdivision 3 of section 66-j of the public service law, as added by chapter 200 of the laws of 2013, is amended to read as follows:
(g) A customer who owns or operates a farm operation as such term is defined in subdivision eleven of section three hundred one of the agriculture and markets law, or a non-residential customer-generator as defined by subparagraph (viii) of paragraph (a) of subdivision one of this section that locates fuel cell electric generating equipment or fuel-flexible linear generator electric generating equipment with a net energy meter on property owned or leased by such customer-generator may designate all or a portion of the net metering credits generated by such equipment to meters at any property owned or leased by such customergenerator within the service territory of the same electric corporation to which the customer-generator's net energy meters are interconnected and being within the same load zone as determined by the location based marginal price as of the date of initial request by the customer-generator to conduct net metering. The electric corporation will credit the accounts of the customer by applying any credits to the highest use meter first, then subsequent highest use meters until all such credits are attributed to the customer. Any excess credits shall be carried over to the following month.
§ 10. Paragraph (b) of subdivision 4 of section 66-j of the public service law, as amended by chapter 494 of the laws of 2014, is amended to read as follows:
S. 1163--A 4
(b) In the event that the amount of electricity produced by a customer-generator during the billing period exceeds the amount of electricity used by the customer-generator, the corporation shall apply a credit to the next bill for service to the customer-generator for the net electricity provided at the same rate per kilowatt hour applicable to service provided to other customers in the same service class which do not generate electricity onsite, except for micro-combined heat and power or fuel cell or fuel-flexible linear generator customer-generators or farm waste generating equipment customer-generators as described in subparagraph (ix) of paragraph (a) of subdivision one of this section, who will be credited at the corporation's avoided costs. The avoided cost credit provided to micro-combined heat and power or fuel cell or fuel-flexible linear generator customer-generators or farm waste generating equipment customer-generators as described in subparagraph (ix) of paragraph (a) of subdivision one of this section shall be treated for ratemaking purposes as a purchase of electricity in the market that is includable in commodity costs.
§ 11. Paragraph (a) of subdivision 5 of section 66-j of the public service law, as amended by chapter 546 of the laws of 2011, is amended to read as follows:
(a) On or before three months after the effective date of this section, each electric corporation shall establish standards that are necessary for net energy metering and the interconnection of residential solar or farm waste electric generating equipment, micro-combined heat and power generating equipment and fuel cell electric generating equipment, fuel-flexible linear generator electric generating equipment and micro-hydroelectric generating equipment to its system and that the commission shall determine are necessary for safe and adequate service and further the public policy set forth in this section. Such standards may include but shall not be limited to:
(i) equipment necessary to isolate automatically the residential solar, farm waste, micro-combined heat and power and fuel cell electric generating system and fuel-flexible linear generator electric generating equipment and micro-hydroelectric generating equipment from the utility system for voltage and frequency deviations; and
(ii) a manual lockable disconnect switch provided by the customer-generator which shall be located on the outside of the customer's premises and externally accessible for the purpose of isolating the residential solar and farm waste electric generating equipment and micro-hydroelectric generating equipment.
§ 12. Subparagraph (i) of paragraph (b) of subdivision 5 of section 66-j of the public service law, as amended by chapter 546 of the laws of 2011, is amended to read as follows:
(i) In the case of a customer-generator who owns or operates solar electric generating equipment located and used at his or her residence; an electric corporation may not require a customer-generator to comply with additional safety or performance standards, perform or pay for additional tests, or purchase additional liability insurance provided that the residential solar or farm waste electric generating equipment, micro-combined heat and power generating equipment, fuel cell electric generating equipment, fuel-flexible linear generator electric generating equipment or micro-hydroelectric generating equipment meets the safety standards established pursuant to this paragraph.
§ 13. This act shall take effect immediately.
Reflowed for reading: line numbers and page breaks removed. Cite the official text.
Sponsor's memo
Title of bill
An act to amend the public service law, in relation to net energy meter- ing for fuel-flexible linear generator electric generating equipment
Summary of provisions
Section 1 of this bill would amend Public Service Law § 66-j throughout to provide parity in net energy metering or fuel-flexible linear genera- tor electric generating equipment. Specifically, the bill would amend:
§ 66-j (1)(a) to include fuel-flexible linear generator electric gener- ating equipment in the definition of "customer generator";
§ 66-j (1)(f) to clarify that this type of technology is included within the definition of "micro-combined heat and power generating equipment";
§ 66-j (1)(i) to add a definition of "fuel-flexible linear generator electric generating equipment" and "fuel flexible linear generator" to mean an integrated system consisting of oscillators, cylinders, elec- tricity conversion equipment and associated balance of plant components that directly convert the linear motion of the oscillators into elec- tricity and which has a combined rated capacity of not more than two thousand kilowatts;
§ 66-j(2)to clarify that an electric corporation shall provide for the interconnection to fuel-flexible linear generator electric generating equipment;
§ 66-j(3) to make conforming changes to add fuel-flexible linear genera- tor electric generating equipment to the list of technologies for which each electric corporation must develop a model contract and file a rate schedule, terms, and conditions for net metering;
§ 66-j(4)to make conforming changes to add fuel-flexible linear genera- tor electric generating equipment to the list of technologies for which an electric corporation must use net metering to measure the charge for the net electricity supplied by the corporation and provided to the corporation by a customer-generator;
§ 66-j(4) to make conforming changes to add fuel-flexible linear genera- tor electric generating equipment to safety standards that electric corporations must establish;
Section 2 of this bill would provide for an immediate effective date.
Justification
In 2019, the New York passed historic climate legislation aimed at reducing greenhouse gasses economy-wide, but especially from the burning of fossil fuels in the electric generation sector. Fuel-flexible tech- nology to reduce emissions is needed now more than ever. One such fuel- flexible technology is the fuel-flexible linear generator, a technology similar to fuel cells that is capable of running on clean and environ- mentally friendly fuels such as hydrogen and bio-diesel. Fuel-flexible linear generators use a low-temperature reaction of air and fuel to drive magnets through copper coils to efficiently produce electricity. As a result, high-efficiency generation can be achieved with near-zero NOx emissions, while maintain full dispatchability to the grid while using hydrogen or renewable fuels. However, while the current law recog- nizes other, similar technologies such as fuel cells, the Public Service Law does not encompass this cutting-edge technology. This bill would amend the Public Service Law to cover this technology for net metering purposes, allowing customers to benefit from clean, dispatchable, gener- ation, ensuring a more stable, secure, and environmentally responsible electric grid, and bringing New York's ambitious carbon neutrality goals within closer reach.
New York has previously provided parity-recognition when it added this technology to the list of equipment eligible for sales tax relief (FY-2017-18 Budget, and most recently, property tax relief pursuant to Chapter 325 of the Laws of 2018.
Legislative history
2019-20: S.8203/A10268-A
Fiscal implications
None
Effective date
This Act shall take effect immediately.
Summaries, headlines and scores are AI-generated from the official bill text. How we score bills. Source: NYS Open Legislation.