Skip to content
S6563Senate2023-2024 SessionSame asA7115

Check School Air Quality

Official title

“Relates to a school ventilation and energy efficiency assessment, repair and verification program”

Sponsor Jeremy CooneySD-56+9 co-sponsorsAffects Education
Status
In Senate Committee
Education
Impact
8/10
Significant
Passage
0%

Bill progress

Step 2 of 7

In committee · Education

What's happening

The bill requires regular assessment, repair, and verification of school ventilation and HVAC systems to improve air quality and energy efficiency, including installation of carbon dioxide monitors, with public reporting and periodic inspections.

Why it matters

  1. Improved public health and learning outcomes. By mandating higher air quality standards and regular monitoring in schools, the bill aims to reduce the spread of airborne illnesses, lower absenteeism, and support better cognitive performance among students and staff.

  2. Accountability and transparency. The bill requires detailed, publicly accessible reports on ventilation and air quality, empowering parents and communities to track whether their schools are meeting safety and efficiency benchmarks.

  3. Workforce standards and job quality. All inspections, repairs, and upgrades must be performed by certified professionals and a “skilled and trained workforce,” which elevates job quality, supports union labor, and ensures that improvements are made by highly qualified personnel.

  4. Long-term cost control and maintenance. By requiring recurring inspections, preventative maintenance plans, and the use of modern, efficient equipment (like MERV 13 filters and CO₂ monitors), the bill helps prevent costly emergency repairs and supports energy efficiency, potentially reducing operational costs for schools over time.

The daily · weekday mornings

Albany, before your first meeting.

Every bill that moved yesterday, summarized in a sentence and ranked by impact. The Albany Scorecard follows on Sundays.

Free. Unsubscribe in one click. Want alerts on specific bills? Create an account.

Headline styles

Check School Air Quality

Plain English, a few words. Used as the page title.

Sponsors

Primary sponsor
Jeremy Cooney

Senator · Senate District 56

Chair, Procurement And ContractsChair, Transportation

History

  1. Referred to education
  2. Referred to education

Companion bill

The same bill in the other chamber. A bill becomes law when one version passes both houses and the governor signs it, so either number can carry it.

A7115Assembly

Require School Air Quality Checks

In Assembly Committee · Education · Sponsor Michael Benedetto

Impact 8 · Significant0% to pass

Full text

8 pagesUnderlined is new[Struck] is removedOfficial text on nysenate.gov ↗

STATE OF NEW YORK

6563

2023-2024 Regular Sessions

IN SENATE

April 26, 2023

Introduced by Sen. COONEY -- read twice and ordered printed, and when printed to be committed to the Committee on Education

AN ACT to amend the education law, in relation to establishing a school ventilation and energy efficiency assessment, repair and verification program

The People of the State of New York, represented in Senate and Assembly, do enact as follows:

Section 1. Legislative findings and intent. The legislature hereby finds and declares that:

a. The issue of ameliorating a school's air quality has gotten a lot of well-deserved attention during the spread of COVID-19 though ventilation and also with the increase of extreme heat conditions in the classrooms. Cleaner air is better for a school building's population and even helps with higher thinking/cognitive abilities. Although schools are now fully open, a school with an outdated or inadequate heating, ventilation, and air conditioning (HVAC) system, which controls the temperature, humidity, and air quality in school classrooms, leave many schools susceptible to harmful airborne particles and, therefore, vulnerable to any current or future contagion that plagues the state. It is important for the state to establish a program which provides for the safe ventilation and proper filtration of air throughout each school building, so they can operate with the confidence that they have safe and efficient HVAC systems in place.

b. The air ventilation and filtration process, essentially, seeks to bring outside air into the school building and then both condition (heat or cool) the outside air and remove any impure air particles as it enters the building (as well as recycling the indoor air). To maintain safety, air particles entering a school must meet minimum standards after going through air purifiers/filters (e.g., MERV 13 filter) and qualified testing personnel and engineers can assess and determine how well a filtration system is working and how safe the air is.

EXPLANATION--Matter in italics (underscored) is new; matter in brackets

[ ] is old law to be omitted.

LBD10932-01-3

c. A program designed to ensure proper school air quality control must include professional assessment, repair and/or replacement of both the HVAC system, as well as carbon dioxide monitors so that any improvements to those systems meet the ventilation rates detailed in the national Uniform Mechanical Code. Reports generated from the continual monitoring of carbon dioxide monitors and maintenance of the HVAC system must also be made available to the public, electronically.

d. Approximately 41% of school districts across the United States of America need HVAC and carbon dioxide system improvements, repairs or updates. Safe air quality levels in public schools protect the health of students and staff, significantly reduce the risk of infectious airborne diseases, increase attendance and improve student performance. Funds allocated through the U.S. Department of Education's Elementary and Secondary Schools Emergency Relief (ESSER) Programs and the Governor's Emergency Education Relief (GEER) Programs and the Department of Health and Humans Services' Head Start and Child Care American Rescue Plan can support improvements to ventilation; repairs, upgrades, and replacements in Heating, Ventilation, and Air Conditioning (HVAC) systems; purchase of MERV 13 air filters, portable air purifiers, and upper-room germicidal ultraviolet irradiation systems; as well as implementation of other public health protocols and CDC guidance.

§ 2. The education law is amended by adding a new section 409-n to read as follows:

§ 409-n. School ventilation and energy efficiency assessment, repair and verification program. 1. For purposes of this section, the following terms shall have the following meanings:

(a) "ANSI" means American National Standards Institute, or its successor.

(b) "ASHRAE" means American Society of Heating, Refrigeration and Air Conditioning Engineers.

(c) "Certified TAB technician" means a technician certified to perform testing, adjusting, and balancing of HVAC systems by the Associated Air Balance Council (AABC), National Environmental Balancing Bureau (NEBB), or the Testing, Adjusting and Balancing Bureau (TABB), or their successors.

(d) "HVAC" means heating, ventilation, and air conditioning.

(e) "Mechanical code" means the most recent version of the Mechanical Code of New York State or, for the City of New York, the most recent version of the New York City Mechanical Code.

(f) "Mechanical engineer" means a professional engineer licensed as a mechanical engineer by the state of New York and who has professional experience with heating, ventilation, and air conditioning systems.

(g) "MERV" means minimum efficiency reporting value, as established by ASHRAE Standard 52.2-2017 -- Method of Testing General Ventilation Air- Cleaning Devices for Removal Efficiency by Particle Size.

(h) "ppm" means parts per million.

(i) "Qualified adjusting personnel" means either of the following:

(i) A certified TAB technician; or

(ii) A skilled and trained workforce under the supervision of a certified TAB technician.

(j) "Qualified testing personnel" means either of the following:

(i) A certified TAB technician; or

(ii) A person certified to perform ventilation verification assessments of heating, ventilation and air conditioning systems from an organization that has been accredited under the ISO/IEC 17024 Personnel Certification standard in ventilation verification assessments.

(k) "Registered apprenticeship program" means an apprenticeship program registered with the department of labor.

(l) "School" shall include but not be limited to a school district, public school, board of cooperative educational services, special act school district as defined in section four thousand one of this chapter, approved preschool special education program pursuant to section fortyfour hundred ten of this chapter, schools and programs authorized by articles eighty-one and eighty-nine of this chapter, state-supported schools in accordance with article eighty-five of this chapter, or any public, private or charter primary, secondary education school.

(m) "Skilled and trained workforce" means a workforce where at least sixty percent of the construction workers are graduates of or registered in and attending a registered apprenticeship program for the applicable occupation.

(n) "TAB" means testing, adjusting, and balancing of a HVAC system.

2. Each school shall comply with the procedures set forth in subdivisions three, four, five, six and seven of this section for all occupied buildings under the school's control. These procedures shall be completed within twenty-four months after the effective date of this section and at least once every five years thereafter, as part of the school's building condition survey required pursuant to section four hundred nine-d of this article.

3. Each school shall ensure that qualified testing personnel or qualified adjusting personnel performs the following assessments:

(a) Qualified testing personnel shall review system capacity and airflow to determine the highest minimum efficiency reporting value (MERV) filtration that can be installed without adversely impacting equipment, shall replace or upgrade filters where needed, and shall verify that such filters are installed correctly. Recommendations for additional maintenance in accordance with ASHRAE Standard 62.1- 2022 Section 8 and Table 8--1, frequency of filter replacement, replacement, or upgrades to allow for more protective filtration shall be recorded in the HVAC Assessment Report where filtration meeting or exceeding the protection of MERV 13 filters cannot be met in the current system.

(b) Qualified testing personnel shall assess the ventilation rates in the facility classrooms, auditoriums, gymnasiums, nurses' offices, kitchen or cafeteria areas, restrooms, and other occupied areas to determine whether they meet the minimum ventilation rate requirements set forth in the mechanical code for new construction. Assessment shall include, but not be limited to, the following:

(i) Calculation of the estimated minimum outside air ventilation rates for each occupied area based on the anticipated maximum occupant density, occupancy category, and square footage and the minimum required ventilation rate per occupant. Calculations shall be based on maximum anticipated classroom or other occupied area occupancy rates and determined by the required ventilation rates set forth in the mechanical code for new construction;

(ii) Measurement of outside air, and verification of whether the system provides the minimum outside air ventilation rates calculated in subparagraph (i) of this paragraph;

(iii) Verification of coil velocities and unit discharge air temperatures required to maintain desired indoor conditions and to avoid moisture carry over from cooling coils;

(iv) Verification that separation between outdoor air intakes and exhaust discharge outlets meet the requirements of the mechanical code;

(v) Confirmation that the air handling unit is bringing in outdoor air and removing exhaust air as intended by the system design; and

(vii) Measurement of exhaust air volume for exhaust fans, including restrooms, and verification that exhaust air volume meets system design and the requirements of the mechanical code.

(c) For systems with economizers, qualified testing personnel shall test system economizer dampers for proper operation. Economizer dampers and controls that are not properly functioning shall be repaired by a skilled and trained workforce. Recommendations for additional maintenance, replacement or upgrades shall be recorded in the HVAC assessment report.

(d) If installed, demand control ventilation systems shall be verified by qualified testing personnel for proper operation. Demand control ventilation systems that are not properly functioning shall be repaired by a skilled and trained workforce. If the demand control ventilation system is recommended to be disabled or is unable to provide recommended ventilation rates, the HVAC system must be configured to meet the minimum ventilation rate requirements without use of the demand control ventilation and tested and adjusted to achieve design minimum outside air value. Recommendations for additional maintenance, replacement or upgrades shall be recorded in the HVAC assessment report.

(e) (i) Qualified testing personnel shall: (A) perform survey readings of inlets and outlets to verify all ventilation is reaching the served zone and that there is adequate distribution; (B) verify if inlets and outlets are balanced within tolerance of the system design; and (C) document read values and deficiencies. If the original system design values are not available, qualified testing personnel shall document available information and note unavailability of system design values in the HVAC assessment report.

(ii) Qualified testing personnel shall verify building and space pressure to ensure:

(A) Pressure differential is within tolerance of design, if known.

(B) Building is not over or under pressurized.

(C) If applicable, rooms designated for temporary occupation by sick students or staff shall maintain a negative pressure, or as otherwise designed.

(f) Qualified testing personnel shall verify coil condition, condensate drainage, cooling coil air temperature differential (entering and leaving dry bulb), heat exchanger air temperature differential (entering and leaving dry bulb), and drive assembly condition. Recommendations for additional maintenance in accordance with ASHRAE Standard 62.1- 2022 Section 8 and Table 8--1, replacement or upgrades shall be recorded in the HVAC assessment report.

(g) Qualified testing personnel shall review control sequences to:

(i) verify systems will maintain intended ventilation, temperature, and humidity conditions during school operation; and

(ii) verify a daily flush is scheduled per applicable local or state guidance.

(h) (i) Verification that all classrooms, assembly areas and office spaces intended for more than ten permanent occupants are equipped with a carbon dioxide monitor that:

(A) Is hardwired, plug-in, or battery-operated and mounted to the wall between three and six feet above the floor and at least five feet away from the door and operable windows;

(B) Displays the carbon dioxide readings to the teacher through a display on the device or other means such as a web-based application or cell phone application;

(C) Notifies the teacher and other appropriate school personnel through visual indicator on the monitor (e.g., indicator light) or other alert such as e-mail, text, or cell phone application, when the carbon dioxide levels in the classroom have exceeded 1,100 ppm;

(D) Maintains a record of previous data which includes at least the maximum carbon dioxide concentration measured;

(E) Has a range of 1-5000 ppm; and

(F) Is certified by the manufacturer to be accurate within 75 ppm at 1,000 ppm carbon dioxide concentration and is certified by the manufacturer to require calibration no more frequently than once every five years.

(ii) The technical specifications for carbon dioxide monitors set forth above may be amended by regulation as necessary to reflect available technology and to achieve the intent of this subdivision.

(iii) Classrooms, assembly areas, kitchen or cafeteria areas, and office spaces intended for more than ten permanent occupants that are not equipped with a carbon dioxide monitor meeting the above requirements shall be retrofitted to include such a monitor as part of this assessment.

Reflowed for reading: line numbers and page breaks removed. Cite the official text.

Sponsor's memo

Title of bill

An act to amend the education law, in relation to establishing a school ventilation and energy efficiency assessment, repair and verification program

Purpose

The purpose of the bill is to ensure the air ventilation and filtration process that brings outside air into the school building and then both conditions (heat or cool) the outside air and removes any impure air particles as it enters the building, as well as recycling the indoor air, meets the ventilation rates detailed in the national Uniform Mechanical Code. This is accomplished by establishing a statewide program requiring schools to obtain an assessment of their HVAC system, by qualified testing personnel, that documents the functionality or lack of function of their HVAC system, to obtain a report from a Mechanical Engineer based upon the documentation in the assessment identifying upgrades and replacements recommended to meet the ventilation rates detailed in the national Uniform Mechanical Code, to install or replace HVAC systems as recommended by the Mechanical Engineer, obtain a Verifi- cation report, performed and completed by qualified testing personnel, that the new system functions as designed and for the installation of CO2 monitors throughout schools to provide ongoing verification that the HVAC systems are functioning as designed.

Summary of specific provisions

Section 1: Legislative findings.

Section 2: Creates a new Section 409-N in the education law to create the School Ventilation and Energy Efficiency Assessment, Repair, and Verification Program and provides for an HVAC assessment report, a mechanical engineering report, requires adjustments, repairs, upgrades, and replacements as recommended in the mechanical engineering report and verification of all work completed pursuant to this section, as well as:

*Provides for periodic inspections and ongoing maintenance; and

*Directs the Commissioner to adopt rules and regulations.

Section 3: Severability.

Section 4: Effective date.

Justification

Approximately 41% of school districts across the United States are in need of HVAC and carbon dioxide system improvements, repairs, or updates. New York State's schools are no exception, and the exact scope of the problem in New York State is not known because there is no requirement to assess these systems. Safe air quality levels in public schools protect the health of students and staff, significantly reduce the risk of infectious airborne diseases, increase attendance and improve student performance.The issue of ameliorating a school's air quality has received a lot of well-deserved attention during the spread of COVID and with the increase of extreme heat conditions in the class- rooms. A school with an outdated or inadequate heating, ventilation, and air conditioning (HVAC) system, which controls the temperature, humidi- ty, and air quality in school classrooms, leave many schools susceptible to harmful airborne particles and, therefore, vulnerable to any current or future contagion that plagues the state, and lower student perform- ance and staff productivity. To ensure proper school air quality, New York State must create a statewide program that includes professional assessment, require the verified repair and/or replacement of HVAC system, as well as provide for ongoing monitoring, with publicly acces- sible data, to ensure any improvements to those systems meet the venti- lation rates on an ongoing basis.

Legislative history

New bill

Fiscal implications

Potential for schools to need to invest in new HVAC systems as required to comply with minimum standards in the National Mechanical Code.

Effective date

This act shall take effect immediately.

Summaries, headlines and scores are AI-generated from the official bill text. How we score bills. Source: NYS Open Legislation.